Motor imagery with non-invasive EEG

Survey in the control of mechanical limbs by motor imagery with non-invasive EEG

The number of subjectsFeature extraction methodSoftware typeWhat part of the limbHow many degrees of freedom

DOF

Number of electrodes,

Company of kit

Used frequency rangeFeedbackWhat Artifacts are removedSource codeAfter illness or notAccuracy

(arbitrary metric)

link6An autoregressive (AR) model for assessing the amplitude of the sensorimotor rhythm.BCI2000

 

Robotic arm424

 

8 – 12 Hz

18 – 26 Hz

Haptic feedbackN/ANoNo78.0 %
link12Custom Multilayer PerceptronOpenBCIRobotic unit – small machine485 – 15 HzNo50 Hz

noise filter

NoNo92,1 %
linkN/AN/ANeuroskyRobotic arm6Neurosky mk8 – 12 HzNoN/ANoN/AN/A
link20Hybrid ConvNetCustomMoved platform with Robot  arm10647 – 14 Hz

16 – 26 Hz

Feedback from GUI40 Hz noise filterNoN/A76.9 %
link7Custom neural networkCustomRobot arm4481 – 10 HzNoPass filter 1-10 ГцNoN/A85.2 %
link2short-time fast Fourier transform

(STFFT)

CustomRobot arm4328 – 12 Hz

13 – 30 Hz

NoEye-blinking

pass filter from noise

etc

NoN/AN/A
link4Canonical Variant Analysis (CVA),

Canonical Variant Analysis (CVA)

CustomRobot arm KUKA7640.2 –  16 HzNoLow-pass Butterworth filterNoN/A79.5 %
linkN/AEmotiv Epoc software

Not detail

Emotiv EpocSmall Humanoid Robot3140.2 – 43 HzNo50 Hz

noise filte

NoN/AN/A
linkN/AEmotiv Epoc software

Not detail

EPOC EEG headseRobot armN/A14N/ANoN/ANoN/AN/A
linkN/AOpenBCI software

Not detail

OpenBCIRobot arm488 – 13 HzNo50 Hz

noise filte

NoN/A80%
linkN/AEmotiv Epoc software

Not detail

Emotiv Epoc

 

Robot machine4

 

148 – 12 HzNo50 Hz

noise filte

NoN/AN/A
linkN/ADiscrete Wavelet
Transform (DWT)
CostumSmall Humanoid Robot3320 – 4 Hz,

4 – 8 Hz,

8 – 13 Hz

13 – 30 Hz

Feedback from CCD camera40 Hz

noise filte r

NoN/AN/A
link7Functions of open-source BCI2000

Not detail

(EnobioArm exoskeleton459–15  HzIR cameraN/ANoArm and finger paralysis75 %
linkN/AEmotiv Epoc software

Not detail

EMOTIV  EPOCRobot arm3140.2 – 45 Hz.NoN/ANoN/AN/A
link6Function of

Neuroscan NuAmps Express system

Not detail

Neuroscan NuAmps Express systemRobot arm640 8 – 12 HzEOG, EMGMuscle movementNoNo93.83
link33Custom functions in MATLABBCI2000

 

Robot arm7648 – 13 HzNoNonstationary high-variance signalsNoNo>80%
link8

 

Discrete Fourier Transform (DFT)g.Tec Medical Engineering GmbH,ExoskeletonN/A16 8 – 36 HzBiphasic electrical pulsesProvoking EMG artifactsNoNeurological conditions82.9